Difference between revisions of "B4-Attenuation and Scattering"
From its-wiki.no
Josef.Noll (Talk | contribs) |
Josef.Noll (Talk | contribs) (→⌘ Path loss calculation) |
||
(11 intermediate revisions by the same user not shown) | |||
Line 17: | Line 17: | ||
|[[File:wallattenuation.png|350px]] | |[[File:wallattenuation.png|350px]] | ||
|} | |} | ||
+ | |||
+ | == ⌘Attenuation parameters for 2.4 GHz == | ||
+ | {| class="wikitable" | ||
+ | ! Obstacle | ||
+ | ! Attenuation <math> \alpha_i </math> [dB] || | ||
+ | |- | ||
+ | ||Brick wall with window || 2 | ||
+ | |- | ||
+ | ||Brick wall next to metal door || 3 | ||
+ | |- | ||
+ | || Cinder Block wall || 4 | ||
+ | |- | ||
+ | || Office wall || 6 | ||
+ | |- | ||
+ | || Metal door in office wall || 6 | ||
+ | |- | ||
+ | || Metall door in brick wall || 12.4 | ||
+ | |- | ||
+ | || Floor || 30 | ||
+ | |} | ||
+ | Measurements performed for European building | ||
+ | |||
+ | (Source:Hydra Deliverable D5.4, p 12) | ||
+ | |||
+ | == ⌘ Path loss calculation == | ||
+ | [[File:TableWirelessISM.png|400px|right]] | ||
+ | Hydra pass loss approximation<br/> | ||
+ | <span style="font-size: 140%;"><math> L = 92,4 + 20 \log(d \mathrm{[km]}) + 20 \log(f \mathrm{[GHz]}) + \sum{n_i \alpha_i}</math></span> | ||
+ | |||
+ | * <span style="color:#000B80">relation between fading margin and receiver sensitivity</span> | ||
+ | |||
+ | |||
+ | [[File:PathLossHydra.png|650px]] |
Latest revision as of 14:20, 26 September 2017
Wiki for ITS | ||||||
---|---|---|---|---|---|---|
|
Contents
⌘ Interaction of electromagnetic waves with the Environment
Examples are:
- leaves will mainly interact around 6 Unik/GHz: thickness will attenuate, whereas reflection is due to diameter of leaves
- branches will have main interaction at about 1 Unik/GHz
- the tree trunk will interact with almost all frequencies at 30 Unik/MHz and above.
⌘ Attenuation in walls
Attenuation in material follows typical an exponential behaviour. |
⌘Attenuation parameters for 2.4 GHz
Obstacle | Attenuation [dB] | |
---|---|---|
Brick wall with window | 2 | |
Brick wall next to metal door | 3 | |
Cinder Block wall | 4 | |
Office wall | 6 | |
Metal door in office wall | 6 | |
Metall door in brick wall | 12.4 | |
Floor | 30 |
Measurements performed for European building
(Source:Hydra Deliverable D5.4, p 12)
⌘ Path loss calculation
Hydra pass loss approximation
- relation between fading margin and receiver sensitivity