Difference between revisions of "CITI-Sense-Mob sensor testing"
From its-wiki.no
Seraj.Fayyad (Talk | contribs) |
Seraj.Fayyad (Talk | contribs) (→Status) |
||
Line 45: | Line 45: | ||
* Partial testing for different parts of the sensor. | * Partial testing for different parts of the sensor. | ||
+ | (Notes): | ||
+ | * The sensor needs 15 after turn it on to stabilize its sensing and to provide reliable data. | ||
+ | * Air quality embedded sensors need to be exchanged with new one every 2 year. | ||
caution: | caution: | ||
Line 52: | Line 55: | ||
* list of used commands for sensor configuration in order to simplify and accelerate testing. | * list of used commands for sensor configuration in order to simplify and accelerate testing. | ||
* Mobile SIM card for sensors configuration. | * Mobile SIM card for sensors configuration. | ||
− | * Sensor manual | + | * Sensor manual (uploaded) |
= Dunavnet link = | = Dunavnet link = |
Revision as of 17:37, 10 March 2014
Wiki for ITS | ||||||
---|---|---|---|---|---|---|
|
CITI-Sense-Mob sensor testing
Title | CITI-Sense-Mob sensor testing |
---|---|
Place | UNIK |
Date, Time | 2014/03/03, 0900-1100 |
Contact Person | Josef Noll |
Participants | Seraj Fayyad |
related to Project | Citi-Sense-MOB |
Keywords |
this page was created by Special:FormEdit/Meeting, and can be edited by Special:FormEdit/Meeting/CITI-Sense-Mob sensor testing |
Category:Meeting |
Status
1) earlier tests failed, no sensor signal
Potential reasons
- no power supply, - measure with multimeter
- to little power (effect) to fire up the sensor board - - don't know the power
- communication fails
On-device monitoring
- Tested the sensor with usb directly to pc and checked that there is some communication in a terminal program
- Also, open it and recheck if the sim card is correctly in the slot.
2) second test partially success, no location information, show some measured values
Potential reasons:
- static electricity
Done activities:
- Send SMS to sensor SIM card (40923931), content =<SRVADR>srv.dunavnet.eu</SRVADR>
(goal): change server address to the new one.
- Sensor discharging from static electricity.
- Sensor running without SIM card then with SIM card in order
(goal): force sensor to recheck the SIM card existence
3) third test: Temporal success with location identification and measurements :
location identification failed potential reasons:
- some wire bad connectivity.
Done activities:
- recheck wires connectivity
- static electricity discharging.
- Partial testing for different parts of the sensor.
(Notes):
* The sensor needs 15 after turn it on to stabilize its sensing and to provide reliable data. * Air quality embedded sensors need to be exchanged with new one every 2 year.
caution: sensor used techs for air contents measurement based on the using of ACID (harmful chemical substance) which sometimes cause bad smell.
Needed for future testing:
- list of used commands for sensor configuration in order to simplify and accelerate testing.
- Mobile SIM card for sensors configuration.
- Sensor manual (uploaded)
Dunavnet 3 online data
GUI
Last measured:
Link status
- lab testing 20Dec2013, position: 59.9755117, 11.0535750 (NILU lab)
internal sensor measures: Air_Quality_bike_sensor_parameter