Done activities:
 
Done activities:
* Sensor discharging from static electricity
+
* Send SMS to sensor SIM card (40923931), content =<SRVADR>srv.dunavnet.eu</SRVADR>
 +
  (goal): change server address to the new one.
 +
* Sensor discharging from static electricity.
 
* Sensor running without SIM card then with SIM card in order
 
* Sensor running without SIM card then with SIM card in order
 
   (goal): force sensor to recheck the SIM card existence
 
   (goal): force sensor to recheck the SIM card existence
  
3) third test success with location identification and measurements:
+
3) third test: Temporal success with location identification and measurements :
 +
 
 
location identification failed potential reasons:
 
location identification failed potential reasons:
 
* some wire bad connectivity.
 
* some wire bad connectivity.
Line 41: Line 45:
 
* Partial testing for different parts of the sensor.
 
* Partial testing for different parts of the sensor.
  
 +
4) fourth test:
 +
Without air sensors board the sensor send approximately half of the expected number of sending
 +
 +
Done activities
 +
* Running of sensor without embedded air quality sensors board for four hours.
 +
 +
Result:
 +
* sensor send 114 reading pre 4 hour where sensor settings were configured to send sense read every 1 min.
 +
 +
 +
 +
(Notes):
 +
* The sensor needs 15 after turn it on to stabilize its sensing and to provide reliable data.
 +
* Air quality embedded sensors need to be exchanged with new one every 2 year.
  
 
caution:
 
caution:
sensor used techs for air contents measurement based on the using of ACID (chemical substance)
+
sensor used techs for air contents measurement based on the using of ACID (harmful chemical substance) which sometimes cause bad smell.
 +
 
 +
Needed for future testing:
 +
* list of used commands for sensor configuration in order to simplify and accelerate testing.
 +
* Mobile SIM card for sensors configuration.
 +
* Sensor manual (uploaded)
  
 
= Dunavnet link =
 
= Dunavnet link =
Line 56: Line 79:
 
Last measured:
 
Last measured:
 
* http://srv.dunavnet.eu/rephandler/ecobus/355255040040264
 
* http://srv.dunavnet.eu/rephandler/ecobus/355255040040264
+
* dunavnet - citisense!3
 +
*
 +
 
 +
Raw data from WFS server
 +
* sensor 4 (.xml): [http://ec2-54-171-68-180.eu-west-1.compute.amazonaws.com:8080/citisense/webproxy/allmeasurements/sensorid/194001.xml]
 
   
 
   
 
== Link status ==
 
== Link status ==

Latest revision as of 10:22, 4 November 2014


CITI-Sense-Mob sensor testing

Title CITI-Sense-Mob sensor testing
Place UNIK
Date, Time 2014/03/03, 0900-1100
Contact Person Josef Noll
Participants Seraj Fayyad
related to Project Citi-Sense-MOB
Keywords
this page was created by Special:FormEdit/Meeting, and can be edited by Special:FormEdit/Meeting/CITI-Sense-Mob sensor testing
Category:Meeting



Status

1) earlier tests failed, no sensor signal

Potential reasons

  • no power supply, - measure with multimeter
  • to little power (effect) to fire up the sensor board - - don't know the power
  • communication fails

On-device monitoring

  • Tested the sensor with usb directly to pc and checked that there is some communication in a terminal program
  • Also, open it and recheck if the sim card is correctly in the slot.

2) second test partially success, no location information, show some measured values

Potential reasons:

  • static electricity

Done activities:

  • Send SMS to sensor SIM card (40923931), content =<SRVADR>srv.dunavnet.eu</SRVADR>
  (goal): change server address to the new one.
  • Sensor discharging from static electricity.
  • Sensor running without SIM card then with SIM card in order
  (goal): force sensor to recheck the SIM card existence

3) third test: Temporal success with location identification and measurements :

location identification failed potential reasons:

  • some wire bad connectivity.

Done activities:

  • recheck wires connectivity
  • static electricity discharging.
  • Partial testing for different parts of the sensor.

4) fourth test: Without air sensors board the sensor send approximately half of the expected number of sending

Done activities

  • Running of sensor without embedded air quality sensors board for four hours.

Result:

  • sensor send 114 reading pre 4 hour where sensor settings were configured to send sense read every 1 min.


(Notes):

* The sensor needs 15 after turn it on to stabilize its sensing and to provide reliable data.
* Air quality embedded sensors need to be exchanged with new one every 2 year.

caution: sensor used techs for air contents measurement based on the using of ACID (harmful chemical substance) which sometimes cause bad smell.

Needed for future testing:

  • list of used commands for sensor configuration in order to simplify and accelerate testing.
  • Mobile SIM card for sensors configuration.
  • Sensor manual (uploaded)

Dunavnet link

Dunavnet 3 online data

Screenshot Dunavnet Sensor3.png

GUI


Last measured:

Raw data from WFS server

  • sensor 4 (.xml): [1]

Link status

  • lab testing 20Dec2013, position: 59.9755117, 11.0535750 (NILU lab)

Position external sensor3.png


internal sensor measures: Air_Quality_bike_sensor_parameter